97 research outputs found

    Assessment of hemodynamic conditions in the aorta following root replacement with composite valve-conduit graft

    Get PDF
    This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced

    Left main bronchus compression due to main pulmonary artery dilatation in pulmonary hypertension: two case reports

    Get PDF
    Abstract. Pulmonary arterial dilatation associated with pulmonary hypertension may result in significant compression of local structures. Left main coronary artery and left recurrent laryngeal nerve compression have been described. Tracheobronchial compression from pulmonary arterial dilatation is rare in adults, and there are no reports in the literature of its occurrence in idiopathic pulmonary arterial hypertension. Compression in infants with congenital heart disease has been well described. We report 2 cases of tracheobronchial compression: first, an adult patient with idiopathic pulmonary arterial hypertension who presents with symptomatic left main bronchus compression, and second, an adult patient with Eisenmenger ventricular septal defect and right-sided aortic arch, with progressive intermedius and right middle lobe bronchi compression in association with enlarged pulmonary arteries

    Exercise cardiac MRI unmasks right ventricular dysfunction in acute hypoxia and chronic pulmonary arterial hypertension

    Get PDF
    Background - Coupling of right ventricular (RV) contractility to afterload is maintained at rest in the early stages of pulmonary arterial hypertension (PAH), but exercise may unmask depleted contractile reserves. We assessed whether elevated afterload reduces RV contractile reserve despite compensated resting function using non-invasive exercise imaging. Methods and Results - Fourteen patients with PAH (mean age 39.1 years, 10 females) and 34 healthy control subjects (mean age 35.6 years, 17 females) completed real-time cardiac magnetic resonance imaging during sub-maximal exercise breathing room-air. Controls were then also exercised during acute normobaric hypoxia (FiO2 12%). RV contractile reserve was assessed by the effect of exercise on ejection fraction (RVEF). In control subjects the increase in RVEF on exercise was less during hypoxia (P=0.017), but the response of left ventricular ejection fraction to exercise did not change. Patients with PAH had impaired RV reserve with half demonstrating a fall in RVEF on exercise despite comparable resting function to controls (PAH: rest 53.6{plus minus}4.3% vs exercise 51.4{plus minus}10.7%; controls: rest 57.1{plus minus}5.2% vs exercise 69.6{plus minus}6.1%, P<0.0001). In control subjects the increase in stroke volume index (SVi) on exercise was driven by reduced RV end-systolic volume, whereas PAH patients did not augment SVi, with increases in both end-diastolic and end-systolic volumes. From baseline hemodynamic and exercise capacity variables only VE/VCO2 was an independent predictor of RV functional reserve (P=0.021). Conclusions - Non-invasive cardiac imaging during exercise unmasks depleted RV contractile reserves in healthy adults under hypoxic conditions and PAH patients under normoxic conditions despite preserved ejection fraction

    Deep nested level sets: Fully automated segmentation of cardiac MR images in patients with pulmonary hypertension

    Get PDF
    In this paper we introduce a novel and accurate optimisation method for segmentation of cardiac MR (CMR) images in patients with pulmonary hypertension (PH). The proposed method explicitly takes into account the image features learned from a deep neural network. To this end, we estimate simultaneous probability maps over region and edge locations in CMR images using a fully convolutional network. Due to the distinct morphology of the heart in patients with PH, these probability maps can then be incorporated in a single nested level set optimisation framework to achieve multi-region segmentation with high efficiency. The proposed method uses an automatic way for level set initialisation and thus the whole optimisation is fully automated. We demonstrate that the proposed deep nested level set (DNLS) method outperforms existing state-of-the-art methods for CMR segmentation in PH patients

    Fractal analysis of left ventricular trabeculations is associated with impaired myocardial deformation in healthy Chinese

    No full text
    Background: Left ventricular (LV) non-compaction (LVNC) is defined by extreme LV trabeculation, but is measured variably. Here we examined the relationship between quantitative measurement in LV trabeculation and myocardial deformation in health and disease and determined the clinical utility of semi-automated assessment of LV trabeculations. Methods: Cardiovascular magnetic resonance (CMR) was performed in 180 healthy Singaporean Chinese (age 20–69 years; males, n = 91), using balanced steady state free precession cine imaging at 3T. The degree of LV trabeculation was assessed by fractal dimension (FD) as a robust measure of trabeculation complexity using a semi-automated technique. FD measures were determined in healthy men and women to derive normal reference ranges. Myocardial deformation was evaluated using feature tracking. We tested the utility of this algorithm and the normal ranges in 10 individuals with confirmed LVNC (non-compacted/compacted; NC/C ratio > 2.3 and ≥1 risk factor for LVNC) and 13 individuals with suspected disease (NC/C ratio > 2.3). Results: Fractal analysis is a reproducible means of assessing LV trabeculation extent (intra-class correlation coefficient: intra-observer, 0.924, 95% CI [0.761–0.973]; inter-observer, 0.925, 95% CI [0.821–0.970]). The overall extent of LV trabeculation (global FD: 1.205 ± 0.031) was independently associated with increased indexed LV end-diastolic volume and mass (sβ = 0.35; p  2.3. Conclusion: This study defines the normal range of LV trabeculation in healthy Chinese that can be used to make or refute a diagnosis of LVNC using the fractal analysis tool, which we make freely available. We also show that increased myocardial trabeculation is associated with higher LV volumes, mass and reduced myocardial strain

    Motion-corrected multiparametric renal arterial spin labelling at 3T: Reproducibility and effect of vasodilator challenge

    Get PDF
    Objectives We investigated the feasibility and reproducibility of free-breathing motion-corrected multiple inversion time (multi-TI) pulsed renal arterial spin labelling (PASL), with general kinetic model parametric mapping, to simultaneously quantify renal perfusion (RBF), bolus arrival time (BAT) and tissue T1. Methods In a study approved by the Health Research Authority, 12 healthy volunteers (mean age, 27.6 ± 18.5 years; 5 male) gave informed consent for renal imaging at 3 T using multi-TI ASL and conventional single-TI ASL. Glyceryl trinitrate (GTN) was used as a vasodilator challenge in six subjects. Flow-sensitive alternating inversion recovery (FAIR) preparation was used with background suppression and 3D-GRASE (gradient and spin echo) read-out, and images were motion-corrected. Parametric maps of RBF, BAT and T1 were derived for both kidneys. Agreement was assessed using Pearson correlation and Bland-Altman plots. Results Inter-study correlation of whole-kidney RBF was good for both single-TI (r2 = 0.90), and multi-TI ASL (r2 = 0.92). Single-TI ASL gave a higher estimate of whole-kidney RBF compared to multi-TI ASL (mean bias, 29.3 ml/min/100 g; p <0.001). Using multi-TI ASL, the median T1 of renal cortex was shorter than that of medulla (799.6 ms vs 807.1 ms, p = 0.01), and mean whole-kidney BAT was 269.7 ± 56.5 ms. GTN had an effect on systolic blood pressure (p < 0.05) but the change in RBF was not significant. Conclusions Free-breathing multi-TI renal ASL is feasible and reproducible at 3 T, providing simultaneous measurement of renal perfusion, haemodynamic parameters and tissue characteristics at baseline and during pharmacological challenge

    In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva (TM) composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology

    Get PDF
    BACKGROUND: The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies. METHODS: Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data. RESULTS: The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm(2) (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm(2) • mmHg(−1) • 10(−3)) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer curvature at the angle developed near the suture line. CONCLUSIONS: BioValsalva™ composite valve-conduit prosthesis is potentially comparable to native aortic root in structural design and in many hemodynamic parameters, although it is stiffer. Surgeons should pay more attention to the surgical technique to maximise the reestablishment of normal smooth aortic curvature geometry to prevent unfavourable flow characteristics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0193-6) contains supplementary material, which is available to authorized users

    Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power

    Get PDF
    BACKGROUND: Cardiac phenotypes, such as left ventricular (LV) mass, demonstrate high heritability although most genes associated with these complex traits remain unidentified. Genome-wide association studies (GWAS) have relied on conventional 2D cardiovascular magnetic resonance (CMR) as the gold-standard for phenotyping. However this technique is insensitive to the regional variations in wall thickness which are often associated with left ventricular hypertrophy and require large cohorts to reach significance. Here we test whether automated cardiac phenotyping using high spatial resolution CMR atlases can achieve improved precision for mapping wall thickness in healthy populations and whether smaller sample sizes are required compared to conventional methods. METHODS: LV short-axis cine images were acquired in 138 healthy volunteers using standard 2D imaging and 3D high spatial resolution CMR. A multi-atlas technique was used to segment and co-register each image. The agreement between methods for end-diastolic volume and mass was made using Bland-Altman analysis in 20 subjects. The 3D and 2D segmentations of the LV were compared to manual labeling by the proportion of concordant voxels (Dice coefficient) and the distances separating corresponding points. Parametric and nonparametric data were analysed with paired t-tests and Wilcoxon signed-rank test respectively. Voxelwise power calculations used the interstudy variances of wall thickness. RESULTS: The 3D volumetric measurements showed no bias compared to 2D imaging. The segmented 3D images were more accurate than 2D images for defining the epicardium (Dice: 0.95 vs 0.93, P < 0.001; mean error 1.3 mm vs 2.2 mm, P < 0.001) and endocardium (Dice 0.95 vs 0.93, P < 0.001; mean error 1.1 mm vs 2.0 mm, P < 0.001). The 3D technique resulted in significant differences in wall thickness assessment at the base, septum and apex of the LV compared to 2D (P < 0.001). Fewer subjects were required for 3D imaging to detect a 1 mm difference in wall thickness (72 vs 56, P < 0.001). CONCLUSIONS: High spatial resolution CMR with automated phenotyping provides greater power for mapping wall thickness than conventional 2D imaging and enables a reduction in the sample size required for studies of environmental and genetic determinants of LV wall thickness
    corecore